Model 1500
One Conductor,
500 Amp
|
 |
 |
2 hex nuts included as shown
|
|
Available with external dust seal (Model 1500-1)
Available with stainless steel ball bearing (Model 1500-SS) |
|
Model 1500-1
One Conductor,
500 Amp
with dust seal
|
 |
 |
2 hex nuts included as shown
|
|
Available with stainless steel ball bearing (Model 1500-1-SS) |
|
Mercotac model 1500 series are ideal connectors for high-power applications
such as on plating electrodes and welding cable reels that require more power than the smaller Mercotac model 1250 series connectors.
They come standard with a stainless steel housing. Available with stainless steel ball bearing (1500-SS or 1500-1-SS)
(recommended for wet or corrosive environments).
|
|
|
Model No. |
Terminals |
Voltage AC/DC |
Max Amp Rating |
Max.
Freq. MHz |
Contact Resistance |
Max. RPM |
Temp Max. F (C) /
Min. F (C) |
Rotation Torque (gm-cm) |
Circuit Separation |
1500 |
1 |
N/A |
500 |
200 |
<1m |
 |
|
300 |
140 (60) /-20(-29) |
750 |
N/A |
1500-SS |
1 |
N/A |
500 |
200 |
<1m |
 |
|
300 |
140 (60) /-20(-29) |
750 |
N/A |
1500-1 |
1 |
N/A |
500 |
200 |
<1m |
 |
|
300 |
140 (60) /-20(-29) |
750 |
N/A |
1500-1-SS |
1 |
N/A |
500 |
200 |
<1m |
 |
|
300 |
140 (60) /-20(-29) |
750 |
N/A |
"-1" designator indicates an external dust seal
"-SS" designator indicates stainless steel ball bearing
Safety Note: The stainless steel housing of the 1500 series Mercotac connector at higher voltages is electrically "hot" to the internal conductor.
Model 1500 Accessories |
|
Model 1500 Connections |
Model 1500 Suggested Mounting Methods |
Model 1500 is typically mounted by the threaded stud on either end or by the steel body using a set screw.
When mounting horizontally, mount the Mercotac so the body of the connector rotates.
|
|
Typical Body Mount Dimensions |
MODEL |
HOLE DIAMETER (Ø) * |
DEPTH |
1500, et al |
2.003" (50.9) |
2.50" (63.5) |
|
|
|
Typical Threaded Contact Mount |
1500 (metric) |
M16 X 2.0 |
1.45" (36.8) |
*Inch (mm) Tolerance Ø |
+.001" (+.025) |
|
|
|
-.000" (-.000) |
|
|
|
|
Installation Notes:
- the up arrow should not point
below horizontal
- do not solder to or bend connector
tabs
- avoid lateral forces and
mechanical loads (overly stiff or tight wires)
- do not rigid mount both ends of
connector
- limit mounting eccentricity (runout
/ wobble) to .005" (.13mm)
- provide overload protection within
the circuit
- avoid vibration and bumping
motions
Back
Top Top |
|
|